Telephone +44 (0) 1342 330 470

Monday to Thursday: 08.30 to 17.00 (GMT)
Friday: 08.30 to 12.45 (GMT)

PRODUCT SEARCH
Portal

Passive input isolators



7 Item(s)

per page

Set Descending Direction
  1. /

    IL3422E 20Mbps passive input isolated RS422 transceiver

    The IL3422E offers an exceptional 2V differential output into a 100R load, over the supply range of 4.5V to 5.5V. This means better data integrity over longer cable lengths, even at data rates as high as 20Mbps. The device is also compatible with 3V input supplies, allowing interface to standard microcontrollers without the need for additional level shifting components.  Isolation is achieved through patented IsoLoop technology.

    • 20Mbps data rate
    • RS422
    • 2500 Vrms isolation (1 min)
    • Designed for multi-point transmission on long bus lines
    • UL1577 recognized: IEC 60747-5-5 (VDE 0884) certified.
    More Info
  2. /

    IL3485E 20Mbps passive input isolated RS485 transceiver

    The IL3485E offers an exceptional 1.5V differential output into a 54R load, over the supply range of 4.5V to 5.5V. This means better data integrity over longer cable lengths, even at data rates as high as 20Mbps. The device is also compatible with 3V input supplies, allowing interface to standard microcontrollers without the need for additional level shifting components.  Isolation is achieved through patented IsoLoop technology.

    • 20Mbps data rate
    • RS485
    • 2500 Vrms isolation (1 min)
    • Designed for multi-point transmission on long bus lines
    • UL1577 recognized: IEC 60747-5-5 (VDE 0884) certified.
    More Info
  3. IL600 Series Dual channel digital isolator

    IL600 Series Dual channel digital isolator

    The IL600 series has a passive input which allows the designer to be able to drive the input with a very wide range of voltage inputs. A single resistor is used to set the maximum input current for input voltages above 0.5V. Please note a feed forward 'boost' capacitor of around 10pF must be placed in parallel with the current limiting resistor.

    • 100Mbps data rate
    • Wide input voltage range
    • MSOP, SOIC, PDIP packages
    • 10 ns typical propagation delay
    • UL1577 recognized: IEC 60747-5-5 (VDE 0884) certified.
    More Info
  4. IL600 Series Single channel digital isolator

    IL600 Series Single channel digital isolator

    The IL600 series has a passive input which allows the designer to be able to drive the input with a very wide range of voltage inputs. A single resistor is used to set the maximum input current for input voltages above 0.5V. Please note a feed forward 'boost' capacitor of around 10pF must be placed in parallel with the current limiting resistor.

    • 100Mbps data rate
    • Wide input voltage range
    • MSOP, SOIC, PDIP packages
    • 10 ns typical propagation delay
    • UL1577 recognized: IEC 60747-5-5 (VDE 0884) certified.
    More Info
  5. IL600 Series Three channel digital isolator

    IL600 Series Three channel digital isolator

    The IL600 series has a passive input which allows the designer to be able to drive the input with a very wide range of voltage inputs. A single resistor is used to set the maximum input current for input voltages above 0.5V. Please note a feed forward 'boost' capacitor of around 10pF must be placed in parallel with the current limiting resistor.

    • 100Mbps data rate
    • Wide input voltage range
    • MSOP, SOIC, PDIP packages
    • 10 ns typical propagation delay
    • UL1577 recognized: IEC 60747-5-5 (VDE 0884) certified.
    More Info
  6. IL600A Series Dual channel digital isolator open drain output

    IL600A Series Dual channel digital isolator open drain output

    The IL600 series has a passive input which allows the designer to be able to drive the input with a very wide range of voltage inputs. A single resistor is used to set the maximum input current for input voltages above 0.5V. Please note a feed forward 'boost' capacitor of around 10pF must be placed in parallel with the current limiting resistor.

    • 10Mbps data rate
    • Wide input voltage range
    • MSOP, SOIC, PDIP packages
    • 10 ns typical propagation delay
    • UL1577 recognized: IEC 60747-5-5 (VDE 0884) certified.
    More Info
  7. IL600A Series Single channel digital isolator open drain output

    IL600A Series Single channel digital isolator open drain output

    The IL600 series has a passive input which allows the designer to be able to drive the input with a very wide range of voltage inputs. A single resistor is used to set the maximum input current for input voltages above 0.5V. Please note a feed forward 'boost' capacitor of around 10pF must be placed in parallel with the current limiting resistor.

    • 10Mbps data rate
    • Wide input voltage range
    • MSOP, SOIC, PDIP packages
    • 10 ns typical propagation delay
    • UL1577 recognized: IEC 60747-5-5 (VDE 0884) certified.
    More Info

7 Item(s)

per page

Set Descending Direction