DGH D3100 Analog Voltage Output Module Series

The D3100 voltage output module is part of the DGH's data acquisition module family. This output module converts digital ASCII signal from a host computer, received via RS-232 or RS-485 ports, to analog DC voltage output at the rate of 1000 conversions per second. Six output signal choices are supported (±1V, ±5V, ±10V, ±0-1V, ±0-5V and ±0-10V). The signals can then be used to control annunciators, acutators or other hardware. The D3100 module is a cost-effective model, ideal for simple step function control applications. These modules utilise a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings, meaning the values are maintained in the event of power loss. The D3100 comes pre-set with default values of 300 baud, one start bit, eight data bits, one stop bit, no parity and any address recognized, but these values can be changed by the user. The modules are designed to be compatible with all popular computers utilising RS-232C or RS-485 ports and no software is necessary to start using them, although the utility software is provided. The D3100 can be mounted on a DIN-rail if required (MK-1 mounting kit required) and can be combined with other DGH modules to provide complete customised data acquisition system for given application.

  • Computer-to-analog voltage output module
  • Choice of RS-232 or RS-485 Input
  • Choice of 6 different outputs: ±1V, ±5V, ±10V, 0-1V, 0-5V and 0-10V
  • Communicates using ASCII protocol
  • User-selectable features include analog input range, baud rate, parity type and others
  • Accuracy: ±0.1% of full scale range maximum
  • 12-bit output resolution
  • Span temperature coefficient: ±50ppm/°C maximum
  • 1000 conversions per second
  • Settling time: 300µs typical (1ms maximum)
  • Power requirements: Serial = 0.75W
  • Operating temperature -25°C to +70°C

The applications for the D3100 data acquisition modules include:

  • Motion control
  • Motor speed control
  • Robotic welding control
  • Interfaces to modems
  • Programmable analog source for product test

£0.00 Ex Tax: £0.00

DGH D3100M Modbus Analog Voltage Output Module Series

The D3100M voltage output module is part of the DGH's data acquisition module family. This output module converts digital MODBUS RTU signal from a host computer, received via RS-232 or RS-485 ports, to analog DC voltage output at the rate of 1000 conversions per second. Six output signal choices are supported (±1V, ±5V, ±10V, ±0-1V, ±0-5V and ±0-10V). The signals can then be used to control annunciators, acutators or other hardware. The D3100M module is a cost-effective model, ideal for simple step function control applications, but unlike non-MODBUS version D3100 it also features user-selectable output slew rate and a communications watchdog timer. These modules utilise a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings, meaning the values are maintained in the event of power loss. The D3100M comes pre-set with default values of 300 baud, one start bit, eight data bits, one stop bit, no parity and any address recognized, but these values can be changed by the user. The modules are designed to be compatible with all popular computers utilising RS-232C or RS-485 ports and no software is necessary to start using them, although the utility software is provided. The D3100M can be mounted on a DIN-rail if required (MK-1 mounting kit required) and can be combined with other DGH modules to provide complete customised data acquisition system for given application.

  • Computer-to-analog voltage output module
  • Choice of RS-232 or RS-485 Input
  • Choice of 6 different outputs: ±1V, ±5V, ±10V, 0-1V, 0-5V and 0-10V
  • Communicates using MODBUS RTU protocol
  • Programmable features include output slopes 0.01V/s to 65535V/s and a watchdog timer
  • User-selectable features include analog input range, baud rate, parity type and others
  • Accuracy: ±0.1% of full scale range maximum
  • 12-bit output resolution
  • Span temperature coefficient: ±50ppm/°C maximum
  • 1000 conversions per second
  • Settling time: 300µs typical (1ms maximum)
  • Power requirements: Serial = 0.75W
  • Operating temperature -25°C to +70°C

The applications for the D3100M data acquisition modules include:

  • Motion control
  • Motor speed control
  • Robotic welding control
  • Interfaces to modems
  • Programmable analog source for product test

£0.00 Ex Tax: £0.00

DGH D3200 Analog Current Output Module Series

The D3200 current output module is part of the DGH's data acquisition module family. This output module converts digital ASCII signal from a host computer, received via RS-232 or RS-485 ports, to analog DC voltage output at the rate of 1000 conversions per second. Two output signal choices are supported (4-20mA or 0-20mA). The signals can then be used to control annunciators, acutators or other hardware. The D3200 module is a cost-effective model, ideal for simple step function control applications. These modules utilise a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings, meaning the values are maintained in the event of power loss. The D3200 comes pre-set with default values of 300 baud, one start bit, eight data bits, one stop bit, no parity and any address recognized, but these values can be changed by the user. The modules are designed to be compatible with all popular computers utilising RS-232C or RS-485 ports and no software is necessary to start using them, although the utility software is provided. The D3200 can be mounted on a DIN-rail if required (MK-1 mounting kit required) and can be combined with other DGH modules to provide complete customised data acquisition system for given application.

  • Computer-to-analog voltage output module
  • Choice of RS-232 or RS-485 Input
  • Choice of 2 different outputs: 4-20mA or 0-20mA
  • Communicates using ASCII protocol
  • User-selectable features include analog input range, baud rate, parity type and others
  • Accuracy: ±0.1% of full scale range maximum
  • 12-bit output resolution
  • Span temperature coefficient: ±50ppm/°C maximum
  • 1000 conversions per second
  • Settling time: 300µs typical (1ms maximum)
  • Power requirements: 1W maximum
  • Operating temperature -25°C to +70°C

The applications for the D3200 data acquisition modules include:

  • Motion control
  • Motor speed control
  • Robotic welding control
  • Interfaces to modems
  • Programmable analog source for product test

£0.00 Ex Tax: £0.00

DGH D3200M Modbus Analog Current Output Module Series

The D3200M Modbus current output module is part of the DGH's data acquisition module family. This output module converts digital MODBUS RTU signal from a host computer, received via RS-232 or RS-485 ports, to analog DC voltage output at the rate of 1000 conversions per second. Two output signal choices are supported (4-20mA or 0-20mA). The signals can then be used to control annunciators, acutators or other hardware. The D3200M module is a cost-effective model, ideal for simple step function control applications, but unlike the non-MODBUS version D3200 it also features user-selectable output slew rate and a communications watchdosg timer. These modules utilise a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings, meaning the values are maintained in the event of power loss. The D3200M comes pre-set with default values of 300 baud, one start bit, eight data bits, one stop bit, no parity and any address recognized, but these values can be changed by the user. The modules are designed to be compatible with all popular computers utilising RS-232C or RS-485 ports and no software is necessary to start using them, although the utility software is provided. The D3200M can be mounted on a DIN-rail if required (MK-1 mounting kit required) and can be combined with other DGH modules to provide complete customised data acquisition system for given application.

  • Computer-to-analog voltage output module
  • Choice of RS-232 or RS-485 Input
  • Choice of 2 different outputs: 4-20mA or 0-20mA
  • Communicates using MODBUS RTU protocol
  • Programmable features include output slopes 0.1mA/s to 65535mA/s and a communications watchdog timer
  • User-selectable features include analog input range, baud rate, parity type and others
  • Accuracy: ±0.1% of full scale range maximum
  • 12-bit output resolution
  • Span temperature coefficient: ±50ppm/°C maximum
  • 1000 conversions per second
  • Settling time: 300µs typical (1ms maximum)
  • Power requirements: 1W maximum
  • Operating temperature -25°C to +70°C

The applications for the D3200M data acquisition modules include:

  • Motion control
  • Motor speed control
  • Robotic welding control
  • Interfaces to modems
  • Programmable analog source for product test

£0.00 Ex Tax: £0.00

DGH D4100 Programmable Analog Voltage Output Module Series

The D4100 programmable voltage output module is part of the DGH's data acquisition module family. This output module, same as the D3100 module, converts digital ASCII signal from a host computer, received via RS-232 or RS-485 ports, to analog DC voltage output at the rate of 1000 conversions per second. On the top of all of the D3100 features, it offers higher level functions for controlling output slew rates and programmable options, as well as communications watchdog timer. Six output signal choices are supported (±1V, ±5V, ±10V, ±0-1V, ±0-5V and ±0-10V). The signals can then be used to control annunciators, acutators or other hardware. These modules utilise a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings, meaning the values are maintained in the event of power loss. The D4100 comes pre-set with default values of 300 baud, one start bit, eight data bits, one stop bit, no parity and any address recognized, but these values can be changed by the user. The modules are designed to be compatible with all popular computers utilising RS-232C or RS-485 ports and no software is necessary to start using them, although the utility software is provided. The D4100 can be mounted on a DIN-rail if required (MK-1 mounting kit required) and can be combined with other DGH modules to provide complete customised data acquisition system for given application.

  • Computer-to-analog voltage output module
  • Choice of RS-232 or RS-485 Input
  • Choice of 6 different outputs: ±1V, ±5V, ±10V, 0-1V, 0-5V and 0-10V
  • Fully programmable output slopes (0.01V/s to 10000V/)
  • Programmable data scaling to any units, start up value and watchdog timer
  • True analog readback of output signal (8-bit analog to digital contverter, accuracy of up to 2% of FS)
  • Programmable
  • Communicates using ASCII protocol
  • User-selectable features include analog input range, baud rate, parity type and others
  • Accuracy: ±0.1% of full scale range maximum
  • 12-bit output resolution
  • Span temperature coefficient: ±50ppm/°C maximum
  • 1000 conversions per second
  • Settling time: 300µs typical (1ms maximum)
  • Power requirements: Serial = 0.75W
  • Operating temperature -25°C to +70°C

The applications for the D4100 data acquisition modules include:

  • Motion control
  • Motor speed control
  • Robotic welding control
  • Interfaces to modems
  • Programmable analog source for product test

£0.00 Ex Tax: £0.00

DGH D4200 Programmable Analog Current Output Module Series

The D4200 programmable current output module is part of the DGH's data acquisition module family. This output module, same as the D3200 module, converts digital ASCII signal from a host computer, received via RS-232 or RS-485 ports, to analog DC voltage output at the rate of 1000 conversions per second. On the top of all of the D3200's features, it offers higher level functions for controlling output slew rates and programmable options, as well as communications watchdog timer. Two output signal choices are supported (0-20mA or 4-20mA). The signals can then be used to control annunciators, acutators or other hardware. These modules utilise a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings, meaning the values are maintained in the event of power loss. The D4200 comes pre-set with default values of 300 baud, one start bit, eight data bits, one stop bit, no parity and any address recognized, but these values can be changed by the user. The modules are designed to be compatible with all popular computers utilising RS-232C or RS-485 ports and no software is necessary to start using them, although the utility software is provided. The D4200 can be mounted on a DIN-rail if required (MK-1 mounting kit required) and can be combined with other DGH modules to provide complete customised data acquisition system for given application.

  • Computer-to-analog voltage output module
  • Choice of RS-232 or RS-485 Input
  • Choice of 2 different outputs: 0-20mA or 4-20mA
  • Fully programmable output slopes (0.01mA/s to 10000mA/s)
  • Programmable data scaling to any units, start up value and watchdog timer
  • True analog readback of output signal (8-bit analog to digital contverter, accuracy of up to 2% of FS)
  • Programmable
  • Communicates using ASCII protocol
  • User-selectable features include analog input range, baud rate, parity type and others
  • Accuracy: ±0.1% of full scale range maximum
  • 12-bit output resolution
  • Span temperature coefficient: ±50ppm/°C maximum
  • 1000 conversions per second
  • Settling time: 300µs typical (1ms maximum)
  • Power requirements: 1W maximum
  • Operating temperature -25°C to +70°C

The applications for the D4200 data acquisition modules include:

  • Motion control
  • Motor speed control
  • Robotic welding control
  • Interfaces to modems
  • Programmable analog source for product test

£0.00 Ex Tax: £0.00

DGH D6500 Analog Voltage/Current Output Module

The D6500 2-channel voltage/current output module is part of the DGH's D6000 data acquisition module family. This analog output module generates DC voltage and current signals across voltage ranges of 0-10V, ±10V and current ranges of 0-20mA, 4-20mA, at the rate of 250 conversions per second. Utilising two 12-bit digital-to-analog (DAC) converters, the user is able to select the output signal type for each channel and control both independently via a host computer using the Modbus RTU protocol. A range of additional programmable features is available, such as output slew rate, startup signal value or a communications watchdog times which can be used to move the analog output signal to a known "safe" condition in an event of communication failure. The D6500 output module contains no pots or DIP switches. For extra security, it utilises a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings such as the range, meaning the values are maintained in the event of power loss. The D6500 module is compatible with any commercial software supporting Modbus RTU protocol and is DIN-rail mountable (MK-1 mounting kit required). Combined with other D6000 modules, it provides the complete, customised data acquisition system for given application.

  • 2-channel analog output module
  • Voltage ranges: 0-10V, ±10V
  • Current ranges: 0-20mA, ±20mA
  • Modbus RTU protocol
  • User-selectable features include analog output type and range per channel, output slew rate, startup signal value, communication watchdog timer, baud rate, parity type and others
  • Two 12-bit DAC converters, 250 conversions per second
  • Compatible with all commercial software programs supporting Modbus RTU protocol, including programs from Wonderware, DreamReport, National Instruments Labview, Indusoft and others
  • Accuracy: ±0.1% of the full scale maximum
  • Span temperature coefficient: ±25ppm/°C maximum
  • Settling Time to 0.1% of the full scale: 1mS
  • Communications watchdog timer
  • Current Output Compliance: ±12Vdc
  • Input burnout protection to 250 Vac
  • Power requirements: Serial = 2.1W
  • Operating temperature -25°C to +70°C
  • Mix and match with other D6000 modules to build a complete, customised data acquisition system

The applications for the D6000 data acquisition modules include:

  • Process monitoring and control
  • Remote data logging to any host computer
  • Product testing
  • Direct connection to PLC

£0.00 Ex Tax: £0.00

DGH D7500 Ethernet MODBUS TCP/IP Analog Output Module

The D7500 two-channel analog output module is part of the DGH's D7000 data acquisition module family supporting RJ-45 Ethernet interface and communication via MODBUS TCP/IP protocol. This output module contains two DAC converters generating an output signal from selection of two voltage or two current ranges; the type of signal can be selected independently for each channel and controlled via the host computer using MODBUS RTU protocol. The D7500 output module can be directly connected to and used for controlling a wide range of sensors and annunciators. The D7500 modules also include programmable features such as output slew rate, a communications watchdog timer, startup value and a ADC converter for readback of the output signal. It also features peer-to-peer (P2P) mode, accepting signal directly from an analog input module without the need to involve a host computer. They are also able to upload information to cloud using ThingSpeak platform, and send e-mail notifications via Gmail free e-mail service (a limit value can be set for each channel separately, triggering the notification e-mail). For extra security, it utilises a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings such as the range, meaning the values are maintained in the event of power loss. The D7500 module is compatible with any commercial software supporting Modbus TCP/IP ethernet protocol and is DIN-rail mountable (MK-1 mounting kit required). Combined with other D7000 modules, it provides the complete, customised data acquisition system for given application.

  • 2-channel analog output module
  • Voltage ranges: 0-10V or ±10Vdc
  • Current ranges: 0-20mA or 4-20mA
  • Modbus TCP/IP communication protocol
  • RJ-45 Ethernet inteface - both 10MB and 100MB
  • User-selectable features include analog input range per channel, baud rate, device address, filtering constants and others
  • Programmable features such as output slew rate, a communications watchdog timer, startup value and a 8-bit ADC converter for readback of the output signal
  • Compatible with all commercial software programs supporting Modbus TCP/IP protocol
  • Accuracy: ±0.1%
  • Voltage output drive: 5mA maximum
  • Span temperature coefficient: ±25ppm/°C maximum
  • Input burnout protection to 250 Vac
  • Settling time to 0.1% of the full scale of 1ms.
  • Power requirements: Serial = 2.1W
  • Operating temperature -25°C to +70°C
  • Mix and match with other D7000 modules to build a complete, customised data acquisition system

The applications for the D7000 data acquisition modules include:

  • Process monitoring and control
  • Remote data logging to any host computer
  • Product testing
  • Peer-To-Peer Communication

£0.00 Ex Tax: £0.00

DGH D8500 Analog Voltage/Current Output USB Module

The D8500 2-channel voltage/current output module is part of the DGH's D8000 data acquisition module family with USB interface. This analog output module generates DC voltage and current signals across voltage ranges of 0-10V, ±10V and current ranges of 0-20mA, 4-20mA, at the rate of 250 conversions per second. Utilising 12-bit digital-to-analog (DAC) converter, the user is able to select the output signal type for each channel and control both independently via a host computer using the Modbus RTU protocol. A range of additional programmable features is available, such as output slew rate, startup signal value or a communications watchdog times which can be used to move the analog output signal to a known "safe" condition in an event of communication failure. The D8500 output module contains no pots or DIP switches. For extra security, it utilises a non-volatile EEPROM (Electrically Erasable Programmable Read Only Memory) to store all user-selectable settings such as the range, meaning the values are maintained in the event of power loss. The D8500 module connects to the computer via USB interface and is compatible with any commercial software supporting Modbus RTU protocol and is DIN-rail mountable (MK-1 mounting kit required). Combined with other D8000 modules, it provides the complete, customised data acquisition system for given application.

  • 2-channel analog output module
  • Connects to the computer via USB interface
  • Voltage ranges: 0-10V, ±10V
  • Current ranges: 0-20mA, ±20mA
  • Modbus RTU protocol
  • User-selectable features include analog output type and range per channel, output slew rate, startup signal value, communication watchdog timer, baud rate, parity type and others
  • Two 12-bit DAC converters, 250 conversions per second
  • Compatible with all commercial software programs supporting Modbus RTU protocol, including programs from Wonderware, DreamReport, National Instruments Labview, Indusoft and others
  • Accuracy: ±0.1% of full scale maximum
  • Span temperature coefficient: ±25ppm/°C maximum
  • Settling Time to 0.1% of the full scale: 1ms
  • Communications watchdog timer
  • Current Output Compliance: ±12Vdc
  • Input burnout protection to 250 Vac
  • Power requirements: Serial = 2.1W
  • Operating temperature -25°C to +70°C
  • Mix and match with other D8000 modules to build a complete, customised data acquisition system

The applications for the D8000 data acquisition modules include:

  • Process monitoring and control
  • Remote data logging to any host computer
  • Product testing

£0.00 Ex Tax: £0.00