Motion Control

Isabellenhütte’s innovative solution for battery management system applications – the IsaSCALE IVT-S is a plug-and-play module for precise current and voltage measurement in package fitting into palm of your hand.

Magnetic sensors, digital isolators and low power switch sensors based on spintronic GMR (Giant Magnetoresistance) technology from NVE Corporation, including high temperature models.

Metal clad thick film and wirewould resistors from RARA, including inductive and non-inductive designs, braking resistors.

Range of short- and long sided thin film terminals from Susumu, including models with high power handling capacity, models suppressing the surface temperature and others.

RARA IRN100

Flat Type Metal Clad Wire Wound Resistors
  • Flat and narrow type metal clad wire wound resistor
  • Cement or silicone filling material with an extruded aluminium housing
  • 300mm flying leads
  • Excellent heat dissipation
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C (cement) / +150°C (silicone)
  • Short time overload of 5 x power rating is 5 seconds

RARA IRN150

Flat Type Metal Clad Wire Wound Resistors
  • Flat and narrow type metal clad wire wound resistor
  • Cement or silicone filling material with an extruded aluminium housing
  • 300mm flying leads
  • Excellent heat dissipation
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C (cement) / +150°C (silicone)
  • Short time overload of 5 x power rating is 5 seconds

RARA IRN50

Flat Type Metal Clad Wire Wound Resistors
  • Flat and narrow type metal clad wire wound resistor
  • Cement or silicone filling material with an extruded aluminium housing
  • 300mm flying leads
  • Excellent heat dissipation
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C (cement) / +150°C (silicone)
  • Short time overload of 5 x power rating is 5 seconds

RARA IRV100

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Extruded aluminium vertical housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV1000

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV120

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Extruded aluminium vertical housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV1200

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV150

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Extruded aluminium vertical housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV200

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Extruded aluminium vertical housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV300

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Extruded aluminium vertical housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV400

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Extruded aluminium vertical housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV500

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Extruded aluminium vertical housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV60

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Extruded aluminium vertical housing
  • Short time overload of 5 x power rating is 5 seconds

RARA IRV600

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV80

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Extruded aluminium vertical housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV800

Metal Clad Wire Wound Resistors
  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds

Resources

Related Articles