Industrial

Robust components for industrial applications and automation systems.

Industrial

  • RARA

RARA IRV800

  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds
  • Compliant
  • RARA

RARA IRV1000

  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds
  • Compliant
  • RARA

RARA IRV1200

  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds
  • Compliant
  • RARA

RARA RH25 (Inductive)

  • Inductive Metal clad wire wound resistor
  • Resistance range between 0.27Ω and 25kΩ
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +250°C
  • Cement moulding within aluminium housing
  • Short time overload of 5 x power rating is 5 seconds
  • Mounts on chassis to utilise heat sink effect
[Download not found]
  • Compliant
  • RARA

RARA RH25 (Non-Inductive)

  • Non-Inductive Metal clad wire wound resistor
  • Resistance range between 0.1Ω and 10kΩ
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +250°C
  • Cement moulding within aluminium housing
  • Short time overload of 5 x power rating is 5 seconds
  • Mounts on chassis to utilise heat sink effect
[Download not found]
  • Compliant
  • RARA

RARA RH50 (Inductive)

  • Metal clad wire wound resistor
  • Resistance range between 0.68Ω and 50kΩ
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +250°C
  • Cement moulding within aluminium housing
  • Short time overload of 5 x power rating is 5 seconds
  • Mounts on chassis to utilise heat sink effect
  • Compliant
  • RARA

RARA RH50 (Non-Inductive)

  • Metal clad wire wound resistor
  • Resistance range between 0.2Ω and 20kΩ
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +250°C
  • Cement moulding within aluminium housing
  • Short time overload of 5 x power rating is 5 seconds
  • Mounts on chassis to utilise heat sink effect
  • Compliant
  • RARA

RARA UHPS

rara_uhps_product_image.jpg
  • 4-terminal shunt resistor
  • Resistance options of 0.2mΩ and 1mΩ
  • Tolerances of ±0.05% to ±1%
  • TCR of ±10 ppm/°C
  • Power rating of 100W (on a suitable heat sink)
  • Temperature range from -55°C to +100°C
  • RARA

RARA ULF100C

RARA IRN/ULN/IRF/ULF Flat Type Metal Clad Wire Wound Resistors
  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 1.1kΩ
  • Power rating of 100W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series
  • Compliant
  • RARA

RARA ULF150C

RARA IRN/ULN/IRF/ULF Flat Type Metal Clad Wire Wound Resistors
  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 1.75kΩ
  • Power rating of 150W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series
  • Compliant
  • RARA

RARA ULF200C

RARA IRN/ULN/IRF/ULF Flat Type Metal Clad Wire Wound Resistors
  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 2.2kΩ
  • Power rating of 200W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series
  • Compliant
  • RARA

RARA ULF250C

RARA IRN/ULN/IRF/ULF Flat Type Metal Clad Wire Wound Resistors
  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 2.79kΩ
  • Power rating of 250W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series
  • Compliant
  • RARA

RARA ULF300C

RARA IRN/ULN/IRF/ULF Flat Type Metal Clad Wire Wound Resistors
  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 3.5kΩ
  • Power rating of 300W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series
  • Compliant
  • RARA

RARA ULF400C

RARA IRN/ULN/IRF/ULF Flat Type Metal Clad Wire Wound Resistors
  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 3.08kΩ
  • Power rating of 400W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series
  • Compliant
  • RARA

RARA ULF500C

RARA IRN/ULN/IRF/ULF Flat Type Metal Clad Wire Wound Resistors
  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 2.46kΩ
  • Power rating of 500W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series
  • Compliant
  • RARA

RARA ULH60

RARA Aluminum Housed, Chassis Mount Resistor Model: IRH, IRV, ULH, ULV, ARH, ARV
  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • UL approved
  • Extruded aluminium horizontal housing
  • Short time overload of 5 x power rating is 5 seconds
  • Compliant

RARA IRV800

  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV1000

  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds

RARA IRV1200

  • Metal clad wire wound resistor
  • Option of flying leads, parallel or series connections
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • Cement moulding with an extruded aluminium housing
  • Short time overload of 10 x power rating is 5 seconds

RARA RH25 (Inductive)

  • Inductive Metal clad wire wound resistor
  • Resistance range between 0.27Ω and 25kΩ
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +250°C
  • Cement moulding within aluminium housing
  • Short time overload of 5 x power rating is 5 seconds
  • Mounts on chassis to utilise heat sink effect

RARA RH25 (Non-Inductive)

  • Non-Inductive Metal clad wire wound resistor
  • Resistance range between 0.1Ω and 10kΩ
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +250°C
  • Cement moulding within aluminium housing
  • Short time overload of 5 x power rating is 5 seconds
  • Mounts on chassis to utilise heat sink effect

RARA RH50 (Inductive)

  • Metal clad wire wound resistor
  • Resistance range between 0.68Ω and 50kΩ
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +250°C
  • Cement moulding within aluminium housing
  • Short time overload of 5 x power rating is 5 seconds
  • Mounts on chassis to utilise heat sink effect

RARA RH50 (Non-Inductive)

  • Metal clad wire wound resistor
  • Resistance range between 0.2Ω and 20kΩ
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +250°C
  • Cement moulding within aluminium housing
  • Short time overload of 5 x power rating is 5 seconds
  • Mounts on chassis to utilise heat sink effect

RARA UHPS

  • 4-terminal shunt resistor
  • Resistance options of 0.2mΩ and 1mΩ
  • Tolerances of ±0.05% to ±1%
  • TCR of ±10 ppm/°C
  • Power rating of 100W (on a suitable heat sink)
  • Temperature range from -55°C to +100°C

RARA ULF100C

  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 1.1kΩ
  • Power rating of 100W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series

RARA ULF150C

  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 1.75kΩ
  • Power rating of 150W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series

RARA ULF200C

  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 2.2kΩ
  • Power rating of 200W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series

RARA ULF250C

  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 2.79kΩ
  • Power rating of 250W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series

RARA ULF300C

  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 3.5kΩ
  • Power rating of 300W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series

RARA ULF400C

  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 3.08kΩ
  • Power rating of 400W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series

RARA ULF500C

  • Flat type metal clad wire wound resistor
  • Resistance options from 1Ω up to 2.46kΩ
  • Power rating of 500W (on a heat sink)
  • Tolerance options between ±0.5% and ±10.0%
  • TCR of +260 ppm/°C maximum
  • For Non UL Approval see the IRF Series

RARA ULH60

  • Metal clad wire wound resistor
  • Option of flying leads (tab terminals are standard)
  • Inductive or non-inductive design
  • Insulation resistance of 20MΩ minimum
  • Temperature range of -55°C up to +200°C
  • UL approved
  • Extruded aluminium horizontal housing
  • Short time overload of 5 x power rating is 5 seconds

Related Articles