The CS51 non-incendive low pressure transducer from Core Sensors is a high-strength sensor designed for use in hazardous environments with various approvals and certifications. Available with low pressure ranges from 1 PSI up to 49 PSI with an accuracy of ≤±0.25% BFSL **. The CS51 has a selection of electrical output options, as well as a choice of process connections and wetted materials available with an operating temperature range of -40°C to +80°C and a media temperature range of -40 to +125°C. The Robust design and variety of configurable options make the CS51 series a versatile pressure transducer designed to operate in some of the harshest conditions. Utilising an all welded stainless steel one-piece diaphragm with no internal O-rings or welds, the series also offers a minimum ingress protection of IP65. The CS51 is an excellent solution for applications such as natural gas compression, hydrogen compression and storage, and process control instrumentation.
In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS51 Non-Incendive Pressure Transducer is offered with an integral Turck Mini-Fast electrical connection. When combined with a Turck cordset (with ITC rated cable) and a Turck Lokfast Guard, there is no requirement for conduit to be installed over the cable*. This not only makes installation easy but also makes switching out sensors less cumbersome. Core Sensors can supply all components as a complete package.
*Core Sensors recommends confirming hazardous location installation requirements with your local inspector as each installation is unique.
- Non-incendive low pressure transducer
- Pressure ranges from 1 PSI up to 49 PSI
- Accuracy of ≤±0.25% BFSL at 25°C **
- Stability of ≤±0.25% of FS (1 year)
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 245 PSI (whichever is less)
- Bi-directional pressure ranges available
- Various electrical output option (see tables below for more details)
- Temperature range from −20°C up to +80°C *
- Reverse polarity protection and EMI protection
- One piece design with isolated media
- Wetted materials available in 316L SS and Hastelloy C276 (special order item)
- IP65 minimum rated ***
* Temperature values are dependent on the chosen connection.
** Accuracy includes non-linearity, hysteresis and non-repeatability
*** IP Rating applies when the electrical connector is attached with the appropriate ingress protection and is dependent on the electrical termination selected. Contact us for more information.
Approvals/Certifications for the Core CS51 series include:
- CSA Class I, division 2, groups A, B, C, D T4
- ABS (American bureau of shipping)
- CE
Typical applications for the CS51 non-incendive low pressure transducer series include:
- Natural gas compression
- Oil exploration
- Process control
- Vapor recovery
Performance, Thermal, Environmental & Physical Specifications Table
Attribute | Value |
---|---|
Accuracy at 25°C ** | ≤±0.25% BFSL |
Stability (1 Year) | ≤±0.25% of FS |
Pressure Cycles | 100 million |
Overpressure | 2x minimum |
Burst Pressure | 5x or 245 PSI (whichever is less) |
Operating Temperature | -40°C to +80°C -20°C to +80°C for DIN 43650-A |
Media Temperature | -40°C to +125°C -40°C to +105°C for DIN 43650-A |
Compensated Temperature | 0°C to +55°C |
Storage Temperature | -40°C to +125°C |
TC Zero | ≤±1% of FS ≤ ± 2% of FS (2 PSI & below) |
TC Span | ≤±1% of FS ≤ ± 2% of FS (2 PSI & below) |
EMI / RFI Protection | Yes |
IP Rating ** | IP65 minimum |
Vibration | 10g, 20 to 2000Hz |
Shock | 100g, 11msec, 1/2 sine |
Electrical Specifications (Current)
Attribute | Value |
---|---|
Outputs | 4 to 20mA |
Excitation | 10 to 28VDC |
Current Consumption | 20mA (typical) |
Output Load | 0 to 800Ω at 10 to 28VDC |
Frequency Response | ~250Hz (minimum) |
Zero Offset (of FS) | ≤±0.5% (typical) ±1% maximum |
Span Tolerance (of FS) | ≤±0.5% (typical) ±1% maximum |
Electrical Specifications (Voltage)
Attribute | Value |
---|---|
Outputs | 1 to 5V 1 to 6V |
Excitation | 10 to 28VDC |
Current Consumption | <10mA |
Output Load | 5kΩ (minimum) |
Frequency Response | ~1kHz (minimum) |
Zero Offset (of FS) | ≤±0.5% (typical) ±1% maximum |
Span Tolerance (of FS) | ≤±0.5% (typical) ±1% maximum |
Electrical Specifications (Ratiometric Voltage)
Attribute | Value |
---|---|
Outputs | 0.5 to 4.5V ratiometric |
Excitation | 5VDC ±0.5V |
Current Consumption | <10mA |
Output Load | 5kΩ (minimum) |
Frequency Response | ~1kHz (minimum) |
Zero Offset (of FS) | ≤±0.5% (typical) ±1% maximum |
Span Tolerance (of FS) | ≤±0.5% (typical) ±1% maximum |
Electrical Specifications (Low Power Voltage)
Attribute | Value |
---|---|
Outputs | 0.5 to 2.5V non-ratiometric |
Excitation | 3 to 5VDC unregulated |
Current Consumption | ≤3mA |
Output Load | 5kΩ (minimum) |
Frequency Response | ~1kHz (minimum) |
Zero Offset (of FS) | ≤±0.5% (typical) ±1% maximum |
Span Tolerance (of FS) | ≤±0.5% (typical) ±1% maximum |
Image | Text |
---|---|
Caution must be taken when installing and operating the CS50/CS51/CS54 in known Class I, Division 2 hazardous locations. Please review the Non-Incendive Operating Instructions prior to installation. Any misuse or improper installation may impair the equipment’s intended use and/or protection ratings. Thoroughly read and understand the operating instructions prior to installation. Call us on +44 (0) 1342 330 470 if you are unsure about any of the precautions, instructions or have any other enquiries. |
Core Sensors design and manufacture high-quality sensors for measuring pressure and temperature properties for industrial and hazardous applications worldwide. Core offers solutions for industrial, submersible, differential and hazardous applications in both standard and custom packaging. In-house design and manufacturing capabilities along with strategic manufacturing partners allow Core to create solutions to some of the most complex sensor requirements. Please visit https://core-sensors.com for more information.