CSA

CSA International (Canadian Standards Association) is a member of the CSA Group that provides product testing and certification services for electrical, mechanical, plumbing, gas and a variety of other products.

CSA International certification marks indicate that a product, process or service has been tested to a Canadian or U.S. standard and it meets the requirements of an applicable CSA standard or another recognized document used as a basis for certification.

  • Ametherm
  • Inrush current limiting thermistor
  • Resistance of 2Ω (at 25°C)
  • Maximum steady state current of 18A
  • Maximum recommended energy of 90J
  • Voltage ratings of 120VAC and 240VAC
  • Body temperature of +214°C at maximum current
  • Ametherm
  • Inrush current limiting thermistor
  • Resistance of 40Ω (at 25°C)
  • Maximum steady state current of 5A
  • Maximum recommended energy of 63J
  • Voltage ratings of 120VAC and 240VAC
  • Body temperature of +162°C at maximum current
  • Core Sensors
  • Non-incendive pressure transducer
  • Pressure ranges from 50 PSI to 30,000 PSI
  • Accuracy of ≤±0.25% BFSL at 25°C
  • Stability of ≤±0.25% of FS
  • Pressure cycles of 100 million
  • Overpressure of 2x minimum
  • Burst pressure of 5x or 60,000 PSI
  • Core Sensors
  • Non-incendive low pressure transducer
  • Pressure ranges from 1 PSI up to 49 PSI
  • Temperature range from −20°C up to +80°C *
  • Accuracy of ≤±0.25% BFSL at 25°C **
  • Stability of ≤±0.25% of FS (1 year)
  • Pressure cycles of 100 million
  • Overpressure of 2x minimum
  • Core Sensors
  • Explosion-Proof Pressure Transducer
  • Pressure ranges from 50 PSI to 30,000 PSI
  • One piece diaphragm design – No internal O-rings or welds
  • Factory sealed stainless steel case – Withstands harsh environments
  • Accuracy of ≤±0.25% BFSL at 25°C (<10,000 PSI)
  • Pressure cycles of 100 million
  • Overpressure of 2x minimum
  • Core Sensors
  • Intrinsically safe pressure transducer
  • Pressure ranges available from 50 PSI up to 30,000 PSI
  • Temperature range −40°C to +85°C
  • Accuracy of ≤ ±0.25% BFSL
  • Burst pressure of 5x or 60,000 PSI whichever is less
  • Stability (1 year) of ≤ ±0.25% of FS
  • Pressure cycles of 100 million
  • Core Sensors
  • Intrinsically safe low pressure transducer
  • Pressure ranges from 1 PSI to 49 PSI
  • Accuracy of ≤±0.25% BFSL
  • Stability of ≤±0.25% of FS (1 year)
  • Pressure cycles of 100 million
  • Overpressure of 2x minimum
  • Burst pressure of 5x or 245 PSI
  • Core Sensors
  • Intrinsically safe submersible pressure transducer
  • Pressure ranges from 1 PSI up to 50 PSI
  • Accuracy of ≤±0.25% BFSL
  • Stability of ≤±0.25% of FS (1 year)
  • Pressure cycles of 50 million
  • Overpressure of 2x minimum
  • Burst pressure of 5x or 250 PSI
  • Core Sensors
  • Intrinsically safe differential pressure transducer
  • Differential pressure up to 50 PSI
  • Maximum line pressure of 500 PSI
  • Bi-directional pressure ranges
  • Accuracy of ≤±0.25% BFSL
  • Stability of ≤±0.25% of FS
  • Pressure cycles of 4 million
  • Paine
  • High precision pressure and temperature transmitter with programmable temperature Output: °F or °C
  • Withstands harsh and extreme environments for durability in tough applications
  • Customisable transmitter options available for fit-for-use designs
  • Stellar Technology
  • Multipurpose clevis pin load cell with extra robust electrical connectors
  • Shock and vibration resistant
  • All welded stainless steel construction
  • Standard calibration is 5 points (0, 50%, 100%, 50%, 0) in both tension and compression
  • Temperature effect on zero ±0.008% FSO/°F
  • Temperature effect on span ±0.005% Reading/°F
  • Zero balance ±1% FSO
  • Stellar Technology
  • Shackle ready, rod end load cell
  • In line tension
  • Variety of thread combinations
  • Shock and vibration resistant
  • All welded stainless steel construction
  • 5 point calibration record traceable to NIST (0, 50%, 100%, 50%, 0)
  • Temperature effect on zero ±0.005% FSO/°F
  • Temperature effect on span ±0.005% Reading/°F
  • Zero balance ±1% FSO
  • Weidmüller
  • PCB terminal connector with 2 row female plug
  • Rated current for minimum number of poles 13.4A (IEC) and 9.5A (UL)
  • Dimensions of L1 3.5mm to 76.5mm (depending on the number of poles required)
  • Push in spring connection with integrated push buttons for opening the terminal point
  • Clamping range from 0.14mm² to 1.5mm²
  • Temperature range −50°C up to +120°C
  • CSA and UL 1059 approved, IEC listed
  • Weidmüller
  • Female plug in connector
  • Rated current for minimum number of poles 17A (IEC) and 10A (UL)
  • Dimensions of L1 3.5mm to 80.5mm (depending on the number of poles required)
  • Clamping yoke screw connection
  • Clamping range from 0.08mm² to 1.5mm²
  • Wire connection cross section from AWG 28 to AWG 14
  • Temperature range −50°C up to +100°C
  • CSA and UL 1059 approved, IEC listed
  • Weidmüller
  • PCB terminal connector with female plug
  • Rated current for minimum number of poles 6A (IEC) and 5A (UL)
  • Dimensions of L1 2.5mm to 27.5mm (depending on the number of poles required)
  • Push in spring connection with integrated push buttons for opening the terminal point
  • Wire connection cross section from AWG28 (0.08mm²) to AWG 20 (0.5mm²)
  • Temperature range −40°C up to +105°C
  • CSA and UL 1059 approved, IEC listed
  • Weidmüller
  • Female plug in connector
  • Rated current for minimum number of poles 17.5A (IEC) and 10A (UL)
  • Dimensions of L1 3.5mm to 80.5mm (depending on the number of poles required)
  • Push in spring connection
  • Clamping range from 0.14mm² to 1.5mm²
  • Wire connection cross section from AWG 26 to AWG 16
  • Temperature range −50°C up to +120°C
  • CSA and UL 1059 approved, IEC listed