Data Acquisition Modules

  • DGH
  • Inputs and outputs to 30Vdc, 100mA maximum
  • Short circuit protection to 500mA
  • Programmable communications watchdog timer
  • Peer-to-peer mode, cloud uploading and e-mail notification features
  • Temperature range of -25°C to +70°C
  • DGH
  • 16-bit ADC, 25/20 conversions per second
  • Accuracy: ±0.05% of FS maximum
  • Programmable digital filters
  • Input impedance 20MΩ minimum
  • Temperature range of -25°C to +70°C
  • DGH
  • 16-bit ADC, 25/20 conversions per second
  • Accuracy: ±0.05% of FS maximum
  • Programmable digital filters
  • Input impedance <100Ω (70 typical)
  • Temperature range of -25°C to +70°C
  • DGH
  • 16-bit ADC, 25/20 conversions per second
  • Accuracy (error from all sources at 0-40°C ambient): ±1.5°C maximum (J, K, T, E) or ±3.5°C maximum (R, S, B, C)
  • Programmable digital filters
  • Input impedance 20MΩ minimum
  • Temperature range of -25°C to +70°C
  • DGH
  • 16-bit ADC, 25/20 conversions per second
  • Specification equivalent to input-specific modules D8100, D8200 and D8300
  • Programmable digital filters
  • Temperature range of -25°C to +70°C
  • DGH
  • 12-bit DAC, 250 conversions per second
  • Accuracy: ±0.1%
  • Communications watchdog timer feature
  • Settling time to 0.1% of full scale: 1ms
  • Temperature range of -25°C to +70°C
  • DGH
  • Internal 10K pull-up resistors on each input terminal
  • Logic “0” = 3.5Vdc
  • Isolation 500Vac, input common to system ground
  • Connection via USB interface
  • Temperature range of -25°C to +70°C
  • DGH
  • Open-collector transistor outputs to 30Vdc, 100mA max.
  • Vsat: +0.3Vdc maximum at 100mA
  • Short circuit protection to 500mA
  • Isolation 500Vac, input common to system ground
  • Connection via USB interface
  • Temperature range of -25°C to +70°C
  • DGH
  • 8-bit ADC, 8 conversions per second
  • Accuracy: ±0.02% of FS maximum
  • Resolution: 0.01% of FS (4 digits)
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ±1 count maximum (autozero)
  • Digital filtering
  • Input impedance of ≤±1V input =100MΩ minimum and ≥±5V input =1MΩ minimum
  • Temperature range of -25°C to +70°C
  • DGH
  • 8-bit ADC, 8 conversions per second
  • Accuracy: ±0.04% of FS maximum
  • Resolution: 0.04% of FS
  • Common mode rejection: 100dB at 50/60Hz
  • Zero drift: ±1 count maximum (autozero)
  • Digital filtering
  • Voltage drop: ±0.1V maximum
  • Temperature range of -25°C to +70°C
  • DGH
  • 8-bit ADC, 8 conversions per second
  • Accuracy (error from all sources between 0-40°C ambient): ±1°C maximum for J, K, T or E and ±2.5°C for R, S, B or C
  • Resolution: 1°C
  • Common mode rejection: 100dB at 50/60Hz
  • Lead resistance effect: <20µV per 350Ω
  • Digital filtering
  • Input impedance of 100MΩ minimum
  • Temperature range of -25°C to +70°C
  • DGH
  • 8-bit ADC, 8 conversions per second
  • Accuracy: ±0.01% of reading ±10µs
  • Resolution: 0.005% of reading +0.01Hz
  • Temperature coefficient: ±20ppm/°C
  • Input impedance: 1MΩ minimum
  • Digital filtering
  • Hysteresis: adjustable 10mV to 1V
  • Temperature range of -25°C to +70°C
  • DGH
  • 8-bit ADC, 8 conversions per second
  • Accuracy: ±0.1°C (2252 type) or ±0.2°C (TD series)
  • Resolution: 0.01°C
  • Common mode rejection: 100dB at 50/60Hz
  • Digital filtering
  • Temperature range of -25°C to +70°C
  • DGH
  • 8-bit ADC, 8 conversions per second
  • Accuracy: ±0.05% of full scale maximum
  • 10µV (mV spans), 0.02% of the full scale on V span
  • Common mode rejection: 100dB at 50/60Hz
  • Digital filtering
  • Temperature range of -25°C to +70°C
  • DGH
  • 8 conversions per second
  • Input switching levels: high 3.5V minimum, low 1.0V maximum
  • Vsat: 1.0V maximum at 100mA
  • Inputs/Outputs read/set in parallel
  • Isolated from power supply ground
  • Temperature range of -25°C to +70°C
  • DGH
  • Transparent RS-232 to RS-485 data conversion
  • Baud rates 300 to 115.2k baud
  • Includes termination and biasing resistors
  • Isolated to 500Vrms
  • Temperature range of -25°C to +70°C

Manufacturers

Looking for Data Acquisition Modules?

Looking for Data Acquisition Modules?

The below manufacturers are all of our authorised partners that produce Data Acquisition Modules or related products.

Data Acquisition Modules

We offer a full range of modular data acquisition modules brought to us by Isabellenhütte & DGH. These include:

  • ISAscale Current and Voltage Measurement (IVT-S)
  • Analog Input
  • Analog Output
  • Digital Input/Output
  • Accessories

These products offer a versatile solution extremely popular for high precision current measurement, process monitoring, water & wastewater management, pharmaceutical, scientific laboratories, military, automotive, transportation, energy management, and power utilities.

Need more information? Speak to our technical sales team who can discuss your project or product and provide technical advice. Speak to us now!

Please be advised that due to the ongoing supply issues with raw materials affecting the global electronics industry, as well as an increase in orders received by our manufacturing partners, a large number of products are facing increased lead times in recent months. For the latest lead time and stock availability, please contact one of our engineers who will be happy to discuss lead times further and the potential for alternative parts.