4 to 20mA series
- Steel mill pressure transducer
- Pressures up to 350 Bar
- Accuracy down to ≤±0.25% BFSL
- Pressure cycles of >100 million
- Burst pressure of 10X or 20,000 PSI (whichever is less)
- IP69 protection against high pressure washdown
- Integral snubber protects against pressure transients
- Industrial pressure transducer
- Pressure ranges from vacuum up to 45,000 PSI
- Accuracy down to ≤ ±0.25% BFSL
- Stability (1 year) of ≤ ±0.25% of FS
- Overpressure of 2x minimum
- Temperature range from -40°C to +85°C
- Media Temperature from -40°C to +120°C
- Submersible pressure transducer
- Pressure ranges from 1 to 100 PSI
- Accuracy down to ≤±0.25% BFSL
- Stability (1 year) of ≤±0.25% of FS
- Pressure cycles of 50 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 500 PSI
- Wet/wet differential pressure transducer
- Differential pressure ranges up to 300 PSI
- Line pressure up to 500 PSI
- Accuracy of ≤±0.25% BFSL at 25°C
- Stability of ≤±0.25% of FS
- Pressure cycles of 4 million
- Overpressure of 2x or 500 PSI
- Non-Clogging submersible pressure transducer
- Pressure ranges from 2 PSI to 50 PSI
- Flush diaphragm prevents clogging
- Hastelloy C276 diaphragm material
- IP68 rated
- Operating temperature of -40 to +85°C
- Compensated temperatures from 0 to +55°C
- Industrial temperature transmitter
- RTD sensor type, PT100, Class B
- Media temperature range of -40°C up to +200°C *
- Operating temperature range of -40°C up to +85°C
- Total error at RT & FS of ≤±1%
- Maximum pressure of 5,000 PSI
- Amplified 4-20mA or 1-5V output signal
- Non-incendive pressure transducer
- Pressure ranges from 50 PSI to 30,000 PSI
- Accuracy of ≤±0.25% BFSL at 25°C
- Stability of ≤±0.25% of FS
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 60,000 PSI
- Non-incendive low pressure transducer
- Pressure ranges from 1 PSI up to 49 PSI
- Temperature range from −20°C up to +80°C *
- Accuracy of ≤±0.25% BFSL at 25°C **
- Stability of ≤±0.25% of FS (1 year)
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Non-Incendive Differential Pressure Transducer
- Differential pressure up to 50 PSI
- Line pressure up to 500 PSI
- Accuracy of ≤±0.25% BFSL / ≤±0.5% BFSL (2 PSI & below)
- Overpressure of 2X or 500 PSI (whichever is less)
- Temperature range −40°C to +80°C
- Media temperature of -40 to +125°C
- Explosion-Proof Pressure Transducer
- Pressure ranges from 50 PSI to 30,000 PSI
- One piece diaphragm design – No internal O-rings or welds
- Factory sealed stainless steel case – Withstands harsh environments
- Accuracy of ≤±0.25% BFSL at 25°C (<10,000 PSI)
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Intrinsically safe pressure transducer
- Pressure ranges available from 50 PSI up to 30,000 PSI
- Temperature range −40°C to +85°C
- Accuracy of ≤ ±0.25% BFSL
- Burst pressure of 5x or 60,000 PSI whichever is less
- Stability (1 year) of ≤ ±0.25% of FS
- Pressure cycles of 100 million
- Intrinsically safe low pressure transducer
- Pressure ranges from 1 PSI to 49 PSI
- Accuracy of ≤±0.25% BFSL
- Stability of ≤±0.25% of FS (1 year)
- Pressure cycles of 100 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 245 PSI
- Intrinsically safe submersible pressure transducer
- Pressure ranges from 1 PSI up to 50 PSI
- Accuracy of ≤±0.25% BFSL
- Stability of ≤±0.25% of FS (1 year)
- Pressure cycles of 50 million
- Overpressure of 2x minimum
- Burst pressure of 5x or 250 PSI
- Intrinsically safe differential pressure transducer
- Differential pressure up to 50 PSI
- Maximum line pressure of 500 PSI
- Bi-directional pressure ranges
- Accuracy of ≤±0.25% BFSL
- Stability of ≤±0.25% of FS
- Pressure cycles of 4 million
- 12-bit DAC, 1000 conversions per second
- Accuracy: ±0.1% of FS maximum
- Output Isolation of 500V rms
- Settling time to 0.1% of FS: 300µs typical, 1ms maximum
- Voltage levels of ±30V without damage
- Temperature range of -25°C to +70°C
- Programmable output slopes and watchdog timer
- 12-bit DAC, 1000 conversions per second
- Accuracy: ±0.1% of FS maximum
- Output Isolation of 500V rms
- Settling time to 0.1% of FS: 300µs typical, 1ms maximum
- Voltage levels of ±30V without damage
- Temperature range of -25°C to +70°C